Back to Evidence
Primary experimental recordPositive observation

PMC9952496::ACT055290

pep1

Evidence text

Paper-level observation

Table 5: aurein 1.2 hemolysis 20.56% at MIC for E. coli (16 μM)
tableConfidence: medium

Assay observation

Activity
Toxicity
Subtype
Hemolytic
Measure
hemolysis
Comparator
=
Raw observation
20.56 %
Normalized measurement
=20.56%
Value minimum
Not reported by source
Value maximum
Not reported by source
Target
Horse erythrocytes
Assay method
Not reported by source
Sequence
GLFDIIKKIAESF
Standardization
ready simple

Source publication

A Novel Strategy for the Design of Aurein 1.2 Analogs with Enhanced Bioactivities by Conjunction of Cell-Penetrating Regions.

Antibiotics · 2023

Related peptide identities

Release PepDiana-V1-20260620. The stable record URL can be cited directly in supplementary material and downstream analyses.