OtherAnti-HIVNegative / threshold
Record detail Figure 5B; Table S2. DCANBP-VP 4 on hV1aR. Text: '>2,100-3,900-fold higher EC50 values compared to parent peptides'.
- Measure
- EC50
- Value
- >2,100
- Target
- Homo sapiens
- Assay
- Not reported by source
Angewandte Chemie (International Ed. in English) · 2026
Sequence evidence
CYFQNCPRG
CYFQNCPRG
Experimental observations
Figure 5B; Table S2. DCANBP-VP 4 on hV1aR. Text: '>2,100-3,900-fold higher EC50 values compared to parent peptides'.
Figure 5C; Table S2. DCANBP-VP 4 on hV1bR. Text: '>2,100-3,900-fold higher EC50 values compared to parent peptides'.
Figure 5E; Table S3. DCANBP-VP 4* on hV1aR. Text: '385-fold increase in activity'.
Figure 5F. DCANBP-VP 4 at 100 nM on hOTR. Text: 'most caged photoprobes exhibited no activity at 100 nM'.
Local peptide labels such as P1, PEP1, or peptide 1 are grouped only within this paper and are not assumed to represent the same molecule across publications.